Reference Report
[REF0812-0027-E]
Application
Solar sludge drying plant
Country
France
City
Mortagne au Perche
Representative office
Conductix-Wampfler [F]
Operator
VEOLIA
Technical requirement[s]
Power supply of mobile system for sludge drying with wire guidance
System course
Two linear lines and one curve
Track length [System]
120 m
Product[s]
Conductor Rail, Program 0812 SinglePowerLine
Additional product information
Mechanical structure with kit of standard part (C rail 40 and 63, Slip Ring Assembly and Spring Cable Reel)
Number of poles
5
Current
200 A
Environmental condition[s]
Hot and wet (greenhouse), ammoniac
Additional information
About 10 similar projects between 2009 and 2011
Single pole conductor rail preferably for straight tracks.
Special features
Main applications
Standard application data